Our biggest and best kit for the Metrel DeltaPAT tester!
Inside you'll find everything a PAT tester needs, including the DeltaPAT itself, PAT labels, a barcode scanner so you can speed up your asset management, an eLearning PAT Testing Course including an exam and certificate, and a printer for making your own PAT labels.
Metrel's DeltaPAT is handheld, easy-to-use and has the added benefit of fully downloadable internal memory. This tester is ideal for mid-sized businesses doing in-house PAT testing, as well as large retailers, landlords and anyone else with a larger amount of appliances to test.
On top of that, we also add all of the following PAT essentials:
Take a look at out different DeltaPAT kits in the table below.
Item | PAT Essentials Kit (Bundle 1) >> | PAT Business Kit (Bundle 2) >> | PAT Premium Kit (Bundle 3) >> |
---|---|---|---|
Socket Tester | ✔ | ✔ | ✔ |
eLearning PAT Testing Course - Includes Exam and Certificate | ✔ | ✔ | ✔ |
Microwave Leakage Detector | ✔ | ✔ | ✔ |
2 x 110V Adapters | ✔ | ✔ | ✔ |
3 x IEC Adapters | ✔ | ✔ | ✔ |
5 Piece Insulated Screwdriver Kit | ✔ | ✔ | ✔ |
Passed PAT Testing Labels | 1000x | 1000x | 1000x |
Circular Passed PAT Testing Labels | 500x | 1000x | 1000x |
Cable Wrap Labels | 500x | 500x | 500x |
Failed PAT Testing Labels | 500x | 500x | 500x |
Visual Inspection Labels | ✖ | ✔ | ✖ |
Barcode Scanner | ✖ | ✔ | ✔ |
Barcode Labels | ✖ | 2000x | 2000x |
Metrel A1488 Printer | ✖ | ✖ | ✔ |
Earth Continuity (200mA in to 2.00Ω) | ||
Range | Resolution | Accuracy |
0.00 Ω ÷ 19.99 Ω | 0.01 Ω | ± (5 % of reading + 3 digits) |
20.0 Ω ÷ 199.9 Ω | 0.1 Ω | Indication Only |
200 Ω ÷ 1999 Ω | 1 Ω | |
Insulation Resistance, Insulation - S Resistance (250VDC, 500VDC) | ||
Range | Resolution | Accuracy |
0.00 MΩ ÷ 19.99 MΩ | 0.01 MΩ | ±(5 % of reading + 3 digits) |
20.0 MΩ ÷ 49.9 MΩ | 0.1 MΩ | |
50.0 MΩ ÷ 199.9 MΩ | 0.1 MΩ | Indication only |
Differential Leakage Current (230VAC) | ||
Range | Resolution | Accuracy |
0.00 mA ÷ 19.99 mA | 0.01 mA | ±(5 % of reading + 5 digits) |
Substitute Leakage Current (30VAC) | ||
Range | Resolution | Accuracy |
0.00 mA ÷ 9.99 mA | 0.01 mA | ±(5 % of reading + 3 digits) |
10.0 mA ÷ 20.0 mA | 0.1 mA | |
(P)RCD testing (10 mA, 15 mA, 30 mA) | ||
Range | Resolution | Accuracy |
0 ms ÷ 300 ms (½xIΔN) | 0.1 ms | ±3 ms |
0 ms ÷ 300 ms (IΔN) | 0.1 ms | |
0 ms ÷ 40 ms (5xIΔN) | 0.1 ms | ±1 ms |
Power measurement (230 VAC) | ||
Range | Resolution | Accuracy |
0.00 kVA ÷ 4.00 kVA | 0.01 kVA | ±(5 % of reading + 3 digits) |
Voltage TRMS Measurement | ||
Range | Resolution | Accuracy |
80 ÷ 300 V | 1 V | ±(2 % of reading + 2 digits) |
Power Supply Voltage | 9 VDC (6x1.5 V battery or accu, size AA), 230 VAC |
Operation | 10 h |
Working Temperature Range | 0 °C ÷ 40 °C |
Maximum Relative Humidity | 95 % RH (0 °C ÷ 40 °C), non-condensing |
Display | 128 x 64 dots matrix display with backlight |
Memory | 1500 memory locations |
Communication Port | RS232 (PS/2 connector, female), USB (connector Type B) |
Overvoltage Category | CAT II / 300 V |
Protection Classification | Double insulation |
Protection Degree | case IP 40 /connectors IP 20 |
Dimensions (W x H x D) | 14 cm x 8 cm x 23 cm |
Weight | 1.2 kg |