FREE - PASS The Complete Guide to EET (PAT) Testing, 5th Edition
Buy a PAT testing kit and get an updated PAT Testing Guide worth £24.99. This 129 page indepth PAT testing book is a great addition to your kit. View PAT Guide
The Megger PAT 150 PAT Tester – PAT Essentials Kit (Bundle 1) is exclusive to PASS. It includes the Megger PAT150 PAT Tester (see the description below) and a selection of additional accessories (see the list below). This kit has been designed for conducting yearly, low-volume PAT testing checks on appliances found in offices, schools and rented property.
What’s Included?
The Megger PAT 150 PAT Tester – PAT Essentials Kit (Bundle 1) includes the Megger PAT150 PAT Tester and accessories:
- Megger PAT150 PAT Tester
- Continuity/ Earth Bond Lead
- SELV/ Mains Voltage Test Lead
- Extension Lead Adapter
- Mains Plug Test Lead
- Carry Case
In addition to this, the Megger PAT 150 PAT Tester – PAT Essentials Kit (Bundle 1) includes the following instruments, tools and accessories:
- Deluxe Carry Case: designed to store the included the Megger PAT150 PAT Tester and Megger’s standard accessories, as well as the additional items included in this kit.
- Socket Tester: instantly detects a variety of wiring faults.
- eLearning PAT Testing Course - Includes Exam and Certificate: provides the user with fully accredited PAT testing training which may be completed at his/her convenience. The fully accredited online exam may also be taken at the user’s convenience and the pass certificate can be printed once completed.
- PASS PAT Testing Logbook: carbon copy logbook allowing the user to record all aspects of the PAT tests performed, including test results.
- Microwave Leakage Detector: designed to check the functionality and radiation emissivity of microwave ovens.
- IEC Adapter Set: facilitates a connection between the Megger PAT 150 PAT Tester and IEC-type appliances and leads, such as computers and/or laptop power supplies.
- CK Tools AVO5050 5 Piece Insulated Screwdriver Kit: a set of five high-quality screwdrivers all of which are fully insulated to 1000V. Ideal for electricians.
- 500 x Passed PAT Testing Labels: for placing on appliances that have passed the PAT testing procedure.
- 500 x Circular Passed PAT Testing Labels: smaller, circular design makes these labels ideal for attaching onto plugs and smaller appliances in order to indicate that they have passed the PAT testing procedure.
- 250 x Cable Wrap PAT Labels: designed to wrap around cables in order to indicate that they have been PAT tested.
- 250 x Failed PAT Testing Labels: to be attached to appliances which have failed the PAT testing procedure. These appliances should be removed from use immediately and sent for repair or replaced.
Megger PAT150 PAT Tester Description
The Megger PAT150 PAT Tester is an upgraded version of the Megger PAT120 PAT Tester. It can be used to test portable fixed appliances and includes a number of features and functions not found on the Megger PAT120, such as:
- RCD (PRCDs) tests for 10mA and 30mA RCDs. This tester will not trip external RCDs and can check both 10mA and 30mA RCDs for disconnection times and the manual test button function.
- Test group pass limits are user-customisable
- Null bond lead resistance to prevent measurement errors
- Live circuit measurements for testing mains supply and socket polarity or electrical circuit voltage to 300V AC
- The Quick Test button can be used to conduct tests for continuity, insulation and mains powered leakage, as well as SELV measurements
- SELV can be measured to 50V AC and includes a PASS/FAIL indicator
- Mains powered leakage test; when performing this test the equipment-under-investigation will remain functional
- NiMH batteries can be recharged while fitted to the PAT tester
This instrument also includes a number of testing capabilities and measurement functions found on the Megger PAT120. These include:
- Test groups for Class I, Class II and Extension/ Power Leads
- Test groups ensure that the correct sequence of tests is performed for the type of appliance under test
- 500V default insulation test
- 250V selectable insulation test
- Substitute/ alternative leakage test (does not require a mains power supply)
- Can maintain the necessary test voltage down to 0.5MΩ when conducting insulation tests
- Continuity test – performed at 20mA DC in both polarities ensuring compliance with international and UK regulations
Furthermore, like the Megger PAT120 PAT Tester, this instrument may also be powered using AA or NiMH batteries and has a typical battery life of up to four days (if the user is testing 120 assets per day). This makes it suitable for use in environments without an electricity supply.
Its hardy design featuring rubber armoured cases and hardened scratch-proof glass also adds to the practicality of this instrument, ensuring that it can be used in rugged environments such as building sites and warehouses.
The Megger PAT150 PAT Tester is an easy-to-use instrument; it features a simple tick/cross PASS/FAIL indicator and will also fully display all the test results. It is compliant with all UK and European requirements for electrical safety testing, making this instrument particularly well suited to testing low volumes of appliances in a multitude of environments.
Megger PAT150 PAT Tester Key Features
- An upgraded version of the Megger PAT120 PAT tester
- Test fixed appliances
- Test 10mA and 30mA RCDs
- Will not trip external RCDs
- Can test 10mA and 30mA RCDs for disconnection times and manual test button functions
- User-customisable test group pass limits
- Bond lead resistance can be nulled
- Live circuit measurements for testing mains supply, socket polarity and electrical circuit voltage to 300V AC
- Quick Test button for continuity, insulation and mains powered leakage tests
- Quick Test button for SELV measurements
- SELV can be measured to 50V AC
- PASS/FAIL indication for SELV measurements
- Mains powered leakage test
- Equipment-under-investigation remains functional when conducting mains powered leakage tests
- NiMH batteries can be recharged while fitted to the PAT tester
- Class I, Class II and Extension/ Power Lead test groups
- Test groups ensure that the correct test sequence is performed for each appliance type
- 500V default insulation test
- 250V selectable insulation test
- Substitute/ alternative leakage test
- Insulation test voltage is maintained down to 0.5MΩ
- Continuity test – 20mA in both polarities
- Power using AA or NiMH batteries
- Typical battery life of four days (based on testing 120 assets per day)
- Rubber armoured cases
- Hardened scratch-proof glass
- Tick/cross PASS/FAIL indicator
- Displays full test results
- Compliant with UK and European requirements for electrical safety testing
Get More with Our Megger PAT150 PAT Kits!
If you're looking for a comprehensive PAT kit - we've got you covered.
We have two different, great value kit versions of the Megger PAT120 available - take a look at the table below for a closer look about what's in each.
Item Description | Megger PAT150 PAT Essentials Kit (Bundle 1) | Megger PAT150 PAT Tester Professional Kit (Bundle 2) |
---|---|---|
Deluxe Carrying Case Keep all of your equipment safe and in one place with this large-size carrying case! (appearance of case may vary depending on current stock) |
√ | √ |
Socket Tester Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
√ | √ |
eLearning PAT Testing Course - Includes Exam and Certificate Gain a certificate of competency to carry out PAT testing in just two hours with our online PAT course and exam. Teams of staff may be trained by purchasing the course multiple times; each staff member will be assigned a unique activation code and login. |
√ |
√ |
PASS PAT Testing Logbook Keep a record of all of your testing with our logbook. The book includes carbon-copied records, allowing you to keep one for yourself and give the other to customers or keep for a reference. |
√ | √ |
Microwave Leakage Detector When PAT testing, it's common practice to check microwaves are also not emitting high levels of radiation. With our microwave leakage detector you'll be able to do this testing with ease. |
√ | √ |
PASSPTA21 - IEC (C13 Female) You'll need this adaptor to connect your PAT tester to laptop/PC power leads and other similar equipment which has a cloverleaf-shaped connector. |
√ | √ |
PASSPTA29 - IEC Plug (C14) This adaptor is used to connect to laptop power supplies, portable projectors and other similar equipment. |
√ | √ |
PASSPTA28 - IEC Plug (C14) You'll find several appliances such as game consoles, laptop power supplies, audio/visual equipment and more use this type of connector - with this adaptor, you can connect them up to your PAT tester. |
√ | √ |
CK Tools AV05050 5 Piece Insulated Screwdriver Kit A handy set of insulated screwdrivers (suitable for live working to 1000V) suitable for a wide variety of applications. |
√ | √ |
WM1 - 500 x Passed PAT Testing Labels You'll need these every time an appliance passes a test - just tear one off, fill in the fields (appliance ID, your name, test date and next test due date) and stick on the appliance when done. |
√ | √ |
WM6500 - 500 x Circular Passed PAT Testing Labels These circular-shaped PAT labels are great for plug tops and any other appliance. The labels also include space for ticking the month/year the next test is due. |
√ | √ |
WM12 250 - 250 x Cable Wrap Labels These passed labels wrap around a wire/cable from an appliance and are recommended for use with power supplies or on appliances where you can't stick a label. They also include space for writing your appliance ID, name, test date and next test date. |
√ | √ |
WM7 250 - 250 x Failed PAT Testing Labels You won't need these as often as your passed labels, but you'll need to apply one of these whenever an appliance fails a test. If it does fail, the item should be taken out of service for repair or replacement |
√ | √ |
SimplyPats Manual PAT Testing Software Keep a database of your PAT testing information on your PC and print reports with SimplyPats Manual software. Please note that this software is manual entry; you cannot download directly from the PAT tester and you will need to type in records by hand. |
- | √ |
- PASS The Complete Guide to EET (PAT) Testing, 5th Edition - PASS-PAT-HB, typically £24.99
Megger PAT100 Series Technical Specifications
Specifications | Megger PAT120 | Megger PAT150 |
---|---|---|
Environmental Conditions | ||
Operating Ambient | 20°C | 20°C |
Humidity | Nominal humidity | Nominal humidity |
Continuity Testing | ||
Test Voltage | Compliance voltage: +4V DC -0 / +10% (open circuit) |
Compliance voltage: +4V DC -0 / +10% (open circuit) |
Test Current | Bi-directional +200mA -0% + 50mA (into 2Ω load) |
Bi-directional +200mA -0% + 50mA (into 2Ω load) |
Continuity Accuracy | Resistance: ±5% ± 3 digits (0 to 19.99Ω) | Resistance: ±5% ± 3 digits (0 to 19.99Ω) |
Resistance Resolution | 10mΩ | 10mΩ |
Display Range | 0.01 to 19.99Ω | 0.01 to 19.99Ω |
Continuity Test Nulling | Up to 9.99Ω | Up to 9.99Ω |
Test Duration | Selected during test automatically | User-selectable from 2 seconds to 20 seconds or selected during test to 180 seconds |
Insulation Test | ||
Insulation Procedure | 250V DC: -0% / +25% open circuit | 250V DC: -0% / +25% open circuit 500V DC: -0% / +25% open circuit ≥ 500V 0% DC across 0.5MΩ load |
Short Circuit/Charge Current | <2mA DC | <2mA DC |
Insulation Accuracy | ±3% ± 10 digits (0 to 99.9MΩ) | ±3% ± 10 digits (0 to 99.9MΩ) |
Resolution | 0.01MΩ | 0.01MΩ |
Display Range | 0.10M to 99.99MΩ | 0.10M to 99.99MΩ |
Test Duration | Selected during test automatically | User selectable from 2 seconds to 20 seconds or selected during test to 180 seconds |
Substitute Leakage Test | ||
Leakage Current | Accuracy ±5% ± 3 digits | Accuracy ±5% ± 3 digits |
Test Frequency | Nominal mains frequency 50Hz | Nominal mains frequency 50Hz |
Test Voltage | <50V AC | <50V AC |
Resolution | 0.01mA | 0.01mA |
Display Range | 0.10 to 19.99mA | 0.10 to 19.99mA |
Test Duration | User-selectable from 2 secs to 5 seconds | User-selectable from 2 secs to 5 seconds |
Differential Leakage Test (PAT150 Only) | ||
Test Voltage | - | Nominal supply voltage 230V AC |
Test Frequency | - | Nominal mains frequency 50Hz |
Test Accuracy | - | ±5% ±3d ± 3μA/A |
Resolution | - | 0.01mA |
Display Range | - | 0.10 to 19.99mA |
Test Duration | - | User-selectable from 2 seconds to 5 seconds |
Touch Current Test (PAT150 Only) | ||
Test Voltage | - | Nominal mains 230V AC |
Test Frequency | - | Nominal mains 50Hz |
Test Accuracy | - | ±5% ± 3 digits |
Resolution | - | 0.01mA |
Display Range | - | 0.10 to 3.99mA |
Test Duration | - | User-selectable from 2 seconds to 5 seconds |
SELV Device Test (PAT150 Only) | ||
Test Voltage | - | 0 to 300V AC |
Measurement Accuracy | - | ±3% ± 3 digits |
Resolution | - | 0.1V AC |
Display Range | - | 0.1 to 300V AC |
Extension Lead Test | ||
Test Voltage | 5V | 5V |
Polarity | Lead OK Live/neutral shorted Live/neutral reversed Live/neutral open circuit |
Lead OK Live/neutral shorted Live/neutral reversed Live/neutral open circuit |
Portable RCD Test (PAT150 Only) | ||
Test Voltage | - | Nominal mains 230V |
Test Frequency | - | 50Hz |
Test Current Accuracy | - | +2% to +8% (1 x I, 5 x I) |
Trip Time Accuracy | - | ±1% ± 1ms |
Trip Time Resolution | - | 0.01ms |
Display Range | - | 0 to 200ms (1 x I) 0 to 40ms (5 x I) |
Mains Supply Test (PAT150 Only) | ||
Frequency Measurement Range | - | 50Hz |
Test Voltage | - | 40 to 300V AC |
Accuracy | - | ±3% ± 3 digits |
Resolution | - | 0.1V AC |
Display Range | - | 40 to 300V AC |
Circuit Test | ||
Test Voltage | 5V | 5V |
Test Frequency | Nominal mains 50Hz | Nominal mains 50Hz |
Test Current | <100mA short circuit | <100mA short circuit |
Safety | Instrument designed to IEC 61010-1: 2012 Test leads designed to IEC 61010-031:2005 300 volts to Earth Category II Mains fuse protection to 250V RMS AC |
Instrument designed to IEC 61010-1: 2012 Test leads designed to IEC 61010-031:2005 300 volts to Earth Category II Mains fuse protection to 250V RMS AC |
EMC | Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005 | Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005 |
Environmental | ||
Operating Temperature | 0 to 40°C | 0 to 40°C |
Storage Temperature | -20 to 60°C | -20 to 60°C |
Humidity | 90% RH @ 10 to 30°C 75% RH @ 30 to 40°C |
90% RH @ 10 to 30°C 75% RH @ 30 to 40°C |
Max Altitude | 2000m to full safety spec | 2000m to full safety spec |
IP Rating | IP40 (with front cover closed) | IP40 (with front cover closed) |
Mechanical (Batteries) | ||
Battery Life | 3 days based on 120 tests/day using 2000mAh alkaline batteries | 3 days based on 120 tests/day using 2000mAh alkaline batteries |
Battery Type | Supply voltage 12V DC (alkaline AA LR6) 9.6V DC (NiMH AA LR6) |
Supply voltage 12V DC (alkaline AA LR6) 9.6V DC (NiMH AA LR6) |
Weight | 1150g | 1300g |
Dimensions | 203mm (L) x 148mm (W) x 78mm (H) | 203mm (L) x 148mm (W) x 78mm (H) |
Reviews
SKU | PAT150BUNDLE1 |
---|---|
Manufacturer Part Code | PAT150BUNDLE1 |