FREE - PASS The Complete Guide to EET (PAT) Testing, 5th Edition
Buy a PAT testing kit and get an updated PAT Testing Guide worth £24.99. This 129 page indepth PAT testing book is a great addition to your kit. View PAT Guide
Martindale HPAT600/2 PAT Tester Kit 1 includes:
In this bundle, you'll receive all standard manufacturer-issued items. That's:
- Martindale HPAT600/2 HandyPAT PAT Tester
- Earth Bond Probe and Croc Clop
- 6x Rechargeable Batteries
- Extension Lead Adapter
- Mains Battery Charger
- 'Test & Go' Carry Case with Separate Pocket for Accessories
- Instruction Manual
- In-car Charger
- Null Pin Key Fob
You will also receive an additional pack from us which includes:
- Deluxe Carrying Case
- Socket Tester
- eLearning PAT Testing Course - Includes Exam and Certificate
- PASS PAT Testing Logbook
- Microwave Leakage Detector
- PASSPTA21 - IEC (C13 Female) to Cloverleaf (C6 Male) PAT Adaptor
- PASSPTA29 - IEC Plug (C14) to Cloverleaf (C5) PAT Adaptor
- PASSPTA28 - IEC Plug (C14) to Fig 8 (C7) PAT Adaptor
- CK Tools AVO5050 5 Piece Insulated Screwdriver Set
- 500 x Passed PAT Testing Labels
- 500 x Circular Passed PAT Testing Labels
- 250 x Cable Wrap Labels
- 250 x Failed PAT Testing Labels
Martindale HandyPAT HPAT600/2 PAT Tester description
This is one of a new range of PAT Testers from Martindale. The Martindale HandyPAT HPAT600/2 PAT Tester is jam-packed full of features found on more expensive PAT Testers, like the ability to set your own pass and fail limits.
The Martindale HandyPAT HPAT600/2 PAT Tester is able to perform 500V insulation tests as well as 250V insulation tests enabling you to test surge protected extension leads and adaptors easily. It is ideal for testing IT equipment and carries out a 200mA Earth Bond Test.
Another feature of the Martindale HPAT600/2 is the ability to carry out testing automatically or manually. In manual mode, a connection diagram is presented on the display and each stage of the test must be confirmed by the user: he/she presses an 'OK' button at each step.
Alternatively, when in automatic mode the HPAT600/2 will run the required test sequence at the push of a button. This instrument is suitable for testing class I and class II appliances, as well as power leads; it includes dedicated function buttons for running each of these test sequences.
Furthermore, the Martindale HandyPAT HPAT6900/2 PAT Tester can perform a simulated load test in order to check the appliance's functionality and the integrity of its fuse. The HPAT600/2 can be used to check 240V appliances, as well as 110V appliances when it is used with an OPTIONAL TL157 adapter. Additionally, the HPAT600/2 can be used with a range of ADDITIONAL adapters to test equipment that terminates in three-phase plugs.
Test results, consisting of numerical readings and a PASS or FAIL decision, are indicated via the backlit display. This tester also has a small memory to store up to 200 test results which can be read back on the screen to write down after testing. Please note that you cannot download data from this PAT Tester.
Martindale HandyPAT HPAT600/2 PAT Tester Features
- Easy to Use
- Safe for IT equipment
- Compatible with surge adapters and extensions
- Backlit display
- 200 manual test memory (not downloadable)
- Battery-powered
- Rechargeable
- Automatic or manual
- Leakage test
- 700 tests on a set of batteries
Martindale HandyPAT HPAT600/2 PAT Tester suitability
- Maintenance Staff
- Schools & Colleges
- Low volume users
- Leisure Industry
- Care Homes
Martindale HPAT600/2 Kit Comparison
Item Description | HPAT600/2 PAT Tester Essentials Kit (Bundle 1) | HPAT600/2 PAT Tester Professional Kit (Bundle 2) |
---|---|---|
Deluxe Carrying Case Keep all of your equipment safe and in one place with this large-size carrying case! (appearance of case may vary depending on current stock) |
√ | √ |
Socket Tester Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
√ | √ |
eLearning PAT Testing Course - Includes Exam and Certificate Gain a certificate of competency to carry out PAT testing in just two hours with our online PAT course and exam. Teams of staff may be trained by purchasing the course multiple times; each staff member will be assigned a unique activation code and login. |
√ |
√ |
The PASS Handbook of Portable Appliance Testing Everything you need to know about PAT testing is outlined in this comprehensive book. Inside, you'll find useful information, colour-coded sections, photographic examples and much more to help you PAT test on a daily basis. |
√ | √ |
PASS PAT Testing Logbook Keep a record of all of your testing with our logbook. The book includes carbon-copied records, allowing you to keep one for yourself and give the other to customers or keep for a reference. |
√ | √ |
Microwave Leakage Detector When PAT testing, it's common practice to check microwaves are also not emitting high levels of radiation. With our microwave leakage detector you'll be able to do this testing with ease. |
√ | √ |
PASSPTA21 - IEC (C13 Female) You'll need this adaptor to connect your PAT tester to laptop/PC power leads and other similar equipment which has a cloverleaf-shaped connector. |
√ | √ |
PASSPTA29 - IEC Plug (C14) This adaptor is used to connect to laptop power supplies, portable projectors and other similar equipment. |
√ | √ |
PASSPTA28 - IEC Plug (C14) You'll find several appliances such as game consoles, laptop power supplies, audio/visual equipment and more use this type of connector - with this adaptor, you can connect them up to your PAT tester. |
√ | √ |
CK Tools AV05050 5 Piece Insulated Screwdriver Kit A handy set of insulated screwdrivers (suitable for live working to 1000V) suitable for a wide variety of applications. |
√ | √ |
WM1 - 500 x Passed PAT Testing Labels You'll need these every time an appliance passes a test - just tear one off, fill in the fields (appliance ID, your name, test date and next test due date) and stick on the appliance when done. |
√ | √ |
WM6500 - 500 x Circular Passed PAT Testing Labels These circular-shaped PAT labels are great for plug tops and any other appliance. The labels also include space for ticking the month/year the next test is due. |
√ | √ |
WM12 250 - 250 x Cable Wrap Labels These passed labels wrap around a wire/cable from an appliance and are recommended for use with power supplies or on appliances where you can't stick a label. They also include space for writing your appliance ID, name, test date and next test date. |
√ | √ |
WM7 250 - 250 x Failed PAT Testing Labels You won't need these as often as your passed labels, but you'll need to apply one of these whenever an appliance fails a test. If it does fail, the item should be taken out of service for repair or replacement |
√ | √ |
SimplyPats Manual PAT Testing Software Keep a database of your PAT testing information on your PC and print reports with SimplyPats Manual software. Please note that this software is manual entry; you cannot download directly from the PAT tester and you will need to type in records by hand. |
- | √ |
- PASS The Complete Guide to EET (PAT) Testing, 5th Edition - PASS-PAT-HB, typically £24.99
Martindale HPAT600/2 Technical Specifications
Earth Continuity | |
Test Voltage | 4V DC (into open circuit) |
Test Current | 200mA DC (into short circuit) |
Range | 0 to 19.99Ω |
Resolution | 0.01Ω |
Accuracy | ± (5% of reading + 2 digits) |
Fixed Pass Limits | |
Lead | ≤ 0.10 Ω = PASS > 0.10Ω ≤ 0.20Ω = NOTE x.xx PASS* |
Class I | Class I ≤ 0.10 Ω = PASS > 0.10Ω ≤ 0.20Ω = NOTE x.xx PASS* |
Note | *Allows user defined pass values to be recorded, eg. for long cord lengths. |
User settable limits | ≤0.1Ω to ≤0.9Ω in 0.1Ω steps |
Insulation | |
Test Voltage | User selectable > 250V DC at 1mA / > 500V DC at 1mA (< 312.5V DC open circuit / < 625V DC open circuit) |
Test Current | Test current: 1.5mA (into short circuit) |
Ranges | 2.00MΩ, 20.0MΩ, 200MΩ |
Resolution | 0.01MΩ |
Accuracy | <100MΩ ± (5% reading + 2 digits) >100MΩ ± (10% reading + 2 digits) |
Fixed Pass Levels | Lead: ≥ 1.0 MΩ Class I: ≥ 1.0 MΩ Class II: ≥ 2.0 MΩ |
Pass level | Lead: ≥ 1.0MΩ, Class I: ≥ 1.0MΩ, Class II: ≥ 2.0MΩ |
User Settable PASS level | ≥ 0.3MΩ to ≥ 1MΩ in 0.1MΩ steps ≥ 1MΩ to ≥ 10MΩ in 1MΩ steps |
Fuse Checks | |
Test Voltage | 4V DC (into open circuit) |
Test Current | 200mA DC (into short circuit) |
Pass Level | >2mA |
Simulatted Load Test | |
Test voltage | 4V DC (into open circuit) |
Test current | 200mA DC (into short circuit) |
Accuracy | ± (5% reading + 2 digits) |
Threshold for ‘Simulated Current Hi’ | 16A |
Memory | 200 tests stored for on-screen recall |
General | |
Overload Protection | 300V AC/DC |
Protection class | IP20 |
Safety | Complies to BS EN 61010-1 |
Temperature Range | -10 to 40°C, non-condensing |
Batteries | 6 x 1.2V AA NiMH rechargeable batteries 1800mAh, or greater |
Battery Life | Fully charged, minimum 600 complete tests. The HPAT500 will operate fully from the battery charger in the event of discharged batteries. Do not remove batteries. |
Auto Shut Down | After 10 minutes of inactivity, or when battery low |
Battery Charger Input | 230V 50Hz |
Battery Charger Output | 12VDC at 300mA, 5.5 jack x 2.5 bore centre positive |
Dimensions | 90 x 210 x 54mm |
Weight | Approx 700g (including batteries & leads) |
Reviews
SKU | HPAT600BUNDLE1 |
---|---|
Manufacturer Part Code | HPAT600BUNDLE1 |