One of the smallest PAT testers available, the HPAT600/2 is ideal for porting from test to test and includes a number of useful functions such as built-in memory storage.
Up to 200 individual records can be stored on the HPAT600/2's memory*, making it significantly easier to recall PAT results (particularly useful when testing a large number of appliances during a day's work).
Testing with the HPAT600/2 is easy; either use the built-in automatic function where the tester will automatically cycle through tests, or use the manual function to perform the tests you want. It also includes user-selectable PASS values and will show full testing results alongside PASS/FAIL indication after a test is completed.
This portable appliance tester is suitable for use with 240V and 110V appliances, class I and class II appliances and includes an IT-safe 200mA DC earth bond test with two pass levels. The HPAT600/2 runs on rechargeable batteries and is supplied as standard with mains and in-car chargers.
*Please note that the HPAT600/2's memory is not downloadable to PC.
Martindale HPAT600/2 PAT Tester Key Features
- Entry-level portable appliance tester designed for low-volume testing
- Internal memory capable of storing up to two-hundred results
- Recall data as necessary
- Please note that records cannot be exported to a PC
- Numerical values and a PASS/ FAIL decision are displayed on the backlit, high-contrast screen
- Test a wide variety of appliances
- Pre-programmed test sequences for class I and class II appliances and power leads
- Automatic mode: press the dedicated function button to run the automatic test sequences for the above appliances and leads
- Manual mode with adjustable PASS limits
- A connection diagram is presented on the display (Manual mode)
- When testing in Manual mode, the user must confirm the completion of each test stage by pressing ‘OK’
- Test 240V appliances
- Use with OPTIONAL lead adapters to test 110V appliances and appliances terminating in three-phase plugs
- IT-safe 200mA earth bond test
- Insulation test with selectable test voltages: 250V or 500V
- 250V insulation test allows the user to check appliances with surge protected circuits
- Simulated load test for checking the appliance’s functionality and the integrity of its fuses
- Compact, lightweight design
- Powered by rechargeable batteries
- Supplied with a mains charger and in-car charger
- Comprehensive, compact and convenient portable appliance tester suitable for low volumes of testing
What's Included?
- Martindale HPAT600/2 HandyPAT PAT Tester
- Earth Bond Probe and Croc Clop
- 6x Rechargeable Batteries
- Extension Lead Adapter
- Mains Battery Charger
- 'Test & Go' Carry Case with Separate Pocket for Accessories
- Instruction Manual
- In-car Charger
- Null Pin Key Fob
HPAT600/2 Bundle Offers
If you're PAT testing, you'll need labels, leads and more. Why buy them separately when you can get one of our bundle packs which come with everything included?
We have several offers available for the HPAT600/2 - to see what the difference between each is, use the table below!
Item Description | HPAT600/2 PAT Tester Essentials Kit (Bundle 1) | HPAT600/2 PAT Tester Professional Kit (Bundle 2) |
---|---|---|
Deluxe Carrying Case Keep all of your equipment safe and in one place with this large-size carrying case! (appearance of case may vary depending on current stock) |
√ | √ |
Socket Tester Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
√ | √ |
PAT Testing Training DVD + Not yet trained as a PAT tester? With our training DVD, you can train yourself from the comfort of your own home or workplace! The DVD includes access to our online examination for one person (you can also purchase additional exams for other team members, if needed). |
√ |
√ |
The PASS Handbook of Portable Appliance Testing Everything you need to know about PAT testing is outlined in this comprehensive book. Inside, you'll find useful information, colour-coded sections, photographic examples and much more to help you PAT test on a daily basis. |
√ | √ |
PASS PAT Testing Logbook Keep a record of all of your testing with our logbook. The book includes carbon-copied records, allowing you to keep one for yourself and give the other to customers or keep for a reference. |
√ | √ |
Microwave Leakage Detector When PAT testing, it's common practice to check microwaves are also not emitting high levels of radiation. With our microwave leakage detector you'll be able to do this testing with ease. |
√ | √ |
PASSPTA21 - IEC (C13 Female) You'll need this adaptor to connect your PAT tester to laptop/PC power leads and other similar equipment which has a cloverleaf-shaped connector. |
√ | √ |
PASSPTA29 - IEC Plug (C14) This adaptor is used to connect to laptop power supplies, portable projectors and other similar equipment. |
√ | √ |
PASSPTA28 - IEC Plug (C14) You'll find several appliances such as game consoles, laptop power supplies, audio/visual equipment and more use this type of connector - with this adaptor, you can connect them up to your PAT tester. |
√ | √ |
CK Tools AV05050 5 Piece Insulated Screwdriver Kit A handy set of insulated screwdrivers (suitable for live working to 1000V) suitable for a wide variety of applications. |
√ | √ |
WM1 - 500 x Passed PAT Testing Labels You'll need these every time an appliance passes a test - just tear one off, fill in the fields (appliance ID, your name, test date and next test due date) and stick on the appliance when done. |
√ | √ |
WM6500 - 500 x Circular Passed PAT Testing Labels These circular-shaped PAT labels are great for plug tops and any other appliance. The labels also include space for ticking the month/year the next test is due. |
√ | √ |
WM12 250 - 250 x Cable Wrap Labels These passed labels wrap around a wire/cable from an appliance and are recommended for use with power supplies or on appliances where you can't stick a label. They also include space for writing your appliance ID, name, test date and next test date. |
√ | √ |
WM7 250 - 250 x Failed PAT Testing Labels You won't need these as often as your passed labels, but you'll need to apply one of these whenever an appliance fails a test. If it does fail, the item should be taken out of service for repair or replacement |
√ | √ |
SimplyPats Manual PAT Testing Software Keep a database of your PAT testing information on your PC and print reports with SimplyPats Manual software. Please note that this software is manual entry; you cannot download directly from the PAT tester and you will need to type in records by hand. |
- | √ |
- Essential Bundle (1,000 Labels & Logbook) - PAT-ESSENTIAL-BUNDLE, typically £77.98
- IT Bundle (3 x IEC Adaptors & Socket Tester) - PAT-IT-BUNDLE, typically £46.96
- Tolsen Tools 7-Piece Insulated Screwdriver Set - TS-9900012, typically £16.99
Martindale HPAT600/2 Technical Specifications
Earth Continuity | |
Test Voltage | 4V DC (into open circuit) |
Test Current | 200mA DC (into short circuit) |
Range | 0 to 19.99Ω |
Resolution | 0.01Ω |
Accuracy | ± (5% of reading + 2 digits) |
Fixed Pass Limits | |
Lead | ≤ 0.10 Ω = PASS > 0.10Ω ≤ 0.20Ω = NOTE x.xx PASS* |
Class I | Class I ≤ 0.10 Ω = PASS > 0.10Ω ≤ 0.20Ω = NOTE x.xx PASS* |
Note | *Allows user defined pass values to be recorded, eg. for long cord lengths. |
User settable limits | ≤0.1Ω to ≤0.9Ω in 0.1Ω steps |
Insulation | |
Test Voltage | User selectable > 250V DC at 1mA / > 500V DC at 1mA (< 312.5V DC open circuit / < 625V DC open circuit) |
Test Current | Test current: 1.5mA (into short circuit) |
Ranges | 2.00MΩ, 20.0MΩ, 200MΩ |
Resolution | 0.01MΩ |
Accuracy | <100MΩ ± (5% reading + 2 digits) >100MΩ ± (10% reading + 2 digits) |
Fixed Pass Levels | Lead: ≥ 1.0 MΩ Class I: ≥ 1.0 MΩ Class II: ≥ 2.0 MΩ |
Pass level | Lead: ≥ 1.0MΩ, Class I: ≥ 1.0MΩ, Class II: ≥ 2.0MΩ |
User Settable PASS level | ≥ 0.3MΩ to ≥ 1MΩ in 0.1MΩ steps ≥ 1MΩ to ≥ 10MΩ in 1MΩ steps |
Fuse Checks | |
Test Voltage | 4V DC (into open circuit) |
Test Current | 200mA DC (into short circuit) |
Pass Level | >2mA |
Simulatted Load Test | |
Test voltage | 4V DC (into open circuit) |
Test current | 200mA DC (into short circuit) |
Accuracy | ± (5% reading + 2 digits) |
Threshold for ‘Simulated Current Hi’ | 16A |
Memory | 200 tests stored for on-screen recall |
General | |
Overload Protection | 300V AC/DC |
Protection class | IP20 |
Safety | Complies to BS EN 61010-1 |
Temperature Range | -10 to 40°C, non-condensing |
Batteries | 6 x 1.2V AA NiMH rechargeable batteries 1800mAh, or greater |
Battery Life | Fully charged, minimum 600 complete tests. The HPAT500 will operate fully from the battery charger in the event of discharged batteries. Do not remove batteries. |
Auto Shut Down | After 10 minutes of inactivity, or when battery low |
Battery Charger Input | 230V 50Hz |
Battery Charger Output | 12VDC at 300mA, 5.5 jack x 2.5 bore centre positive |
Dimensions | 90 x 210 x 54mm |
Weight | Approx 700g (including batteries & leads) |
Reviews
SKU | HPAT600 |
---|---|
Manufacturer Part Code | MARHPAT600/2 |
Model No | HPAT600 |