All Kewtech Products

Kewtech SMARTPAT PAT Tester – PAT Essentials Kit (Bundle 1)

SKU
SMARTPATBUNDLE1
Rating:
0%
(0)
Reward Points
:
754
£904.80 £754.00
In Stock
Free UK Delivery*
Choose a Special Offer
  • PASS The Complete Guide to EET (PAT) Testing Cover
    PASS The Complete Guide to EET (PAT) Testing, 5th Edition
    FREE
    £24.99
  • PASS The Complete Guide to EET (PAT) Testing, 5th Edition SKU: (PASS-PAT-HB)
    FREE
    £24.99
    PASS The Complete Guide to EET (PAT) Testing Cover
    • Updated to include 5th Edition revisions
    • Easy-to-understand explanations, illustrated examples, & quick summaries
    • An invaluable resource for both new and experienced technicians
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Free Complete Guide to EET (PAT) Testing
Kewtech SMARTPAT PAT Tester – PAT Essentials Kit (Bundle 1)
PASS PAT Guide

FREE - PASS The Complete Guide to EET (PAT) Testing, 5th Edition

Buy a PAT testing kit and get an updated PAT Testing Guide worth £24.99. This 129 page indepth PAT testing book is a great addition to your kit. View PAT Guide

The Kewtech SMARTPAT PAT Tester – PAT Essentials Kit (Bundle 1) consists of the Kewtech SMARTPAT PAT Tester (supplied with Kewtech’s standard accessories) and an array of additional PAT testing accessories, such as labels, logbook and adapters. For a comprehensive overview of the items included in this bundle, please see the ‘What’s Included?’ section. 

For further information regarding the Kewtech SMARTPAT PAT Tester, please see the following description.

Kewtech SMARTPAT PAT Tester Description

The Kewtech SMARTPAT PAT Tester is a non-downloading, battery-operated PAT tester. It can be converted into a fully downloadable PAT tester when used in conjunction with the Kewtech KEWPAT App (NOT included).

This instrument is suitable for PAT testing extension leads, as well as Class I and Class II appliances with and without electronic on/off switches. To this end, it includes pre-programmed test sequences optimised for extension leads, and Class I and Class II appliances. These pre-programmed test sequences can be run via pressing the clearly labelled function buttons.

In addition to this, the Kewtech SMARTPAT PAT Tester can be used to perform the following portable appliance checks:

  • 200mA continuity check (IT safe)
  • Quick continuity test
  • 5-second continuity test
  • 250V insulation test (IT safe and ideal for testing surge protected extension leads)
  • 500V insulation test
  • Substitute leakage test
  • Polarity check
  • 110V load and run test
  • 230V load and run test
  • Portable RCD test
  • Extension lead test

When the Kewtech SMARTPAT PAT Tester is used with the Kewtech KEWPAT App these tests may be arranged into personalised test sequences, allowing the user to tailor the SMARTPAT to his/her requirements.

Furthermore, as well as its suitability for testing extension leads, and Class I and Class II appliances, the Kewtech SMARTPAT PAT Tester is also optimised for checking 10mA and 30mA RCDs without tripping these components.

The Kewtech SMARTPAT PAT Tester is supplied with an array of accessories which facilitate the user’s ability to adapt the tester to perform the above tests. It is supplied with an EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip, EZYLEAD Extension Lead Adapter, and EZYMAIN Mains Lead.

Adding to its extensive testing capabilities, the Kewtech SMARTPAT PAT Tester also includes a Test Lead Null setting for nullifying test lead resistance in order to attain accurate resistance measurements.  Furthermore, it features an Appliance Pre-check in order to ascertain whether the instrument-under-investigation is powered on or off prior to commencing any checks. This function improves the safety of the Kewtech SMARTPAT PAT Tester and can be used to prevent damage to the instrument and the user.

Measurements and test results are indicated on the Kewtech SMARTPAT PAT Tester’s large, backlit display. Via this display, the user can view a written PASS or FAIL indication as well as a numerical measurement (where applicable). Moreover, the backlight will change colour in order to indicate whether a test has been passed or failed; this light will change to green to indicate a PASS and will change to red to indicate a FAIL.

As indicated above, the Kewtech SMARTPAT PAT Tester is a non-downloading, battery-operated portable appliance tester. It is capable of performing up to 1400 tests over the duration of its replaceable battery’s lifetime. The Kewtech SMARTPAT PAT Tester is an adaptable, comprehensive, and easy-to-use instrument.

Kewtech SMARTPAT PAT Tester Key Features

  • Non-downloading, battery-operated PAT tester
  • Can be converted into a fully downloadable PAT tester when used with the KEWPAT App (NOT included)
  • Suitable for PAT testing extension leads, and Class I and Class II appliances with and without electronic on/off switches
  • Pre-programmed test sequences optimised for extension leads, and Class I and Class II appliances
  • Run the pre-programmed test sequences by pressing the clearly labelled function buttons
  • 200mA continuity check (IT safe)
  • Quick continuity test
  • 5-second continuity test
  • 250V insulation test (IT safe and ideal for testing surge protected extension leads)
  • 500V insulation test
  • Substitute leakage test
  • Polarity check
  • 110V load and run test
  • 230V load and run test
  • Portable RCD test
  • Extension lead test
  • Use with the KEWPAT App to create personalised test sequences
  • Can check 10mA and 30mA RCDs without tripping these components
  • Supplied with an EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip, EZYLEAD Extension Lead Adapter, and EZYMAIN Mains Lead
  • Test Lead Null setting
  • Appliance Pre-check
  • Large, backlit display
  • View a written PASS or FAIL indication and numerical measurement (where applicable) via the display
  • The backlight will change colour in order to indicate when a test has been passed or failed
  • Green backlight = PASS
  • Red backlight = FAIL
  • Perform up to 1400 tests over the course of the replaceable battery’s lifetime
  • An adaptable, comprehensive, easy-to-use instrument

What’s Included in the Kewtech SMARTPAT PAT Tester – PAT Essentials Kit (Bundle 1)?

  • Kewtech SMARTPAT PAT Tester
  • EZYLEAD Extension Lead Adapter (from Kewtech)
  • EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip (from Kewtech)
  • EZYMAIN Mains Lead (from Kewtech)
  • Carry Bag with Strap (from Kewtech)
  • Quick Start Guide (from Kewtech)
  • End of Line Calibration Certificate (from Kewtech)
  • Deluxe Carrying Case
  • Socket Tester
  • eLearning PAT Testing Course - Includes Exam and Certificate
  • PASS PAT Testing Logbook
  • Microwave Leakage Detector
  • PASSPTA21 – IEC (C13 Female) to Cloverleaf (C6 Male) PAT Adapter
  • PASSPTA29 – IEC Plug (C14) to Cloverleaf (C5) PAT Adapter
  • PASSPTA28 – IEC Plug (C14) to Fig 8 (C7) PAT Adapter
  • CK Tools AVO5050 5 Piece Insulated Screwdriver Set
  • 500 x Passed PAT Testing Labels
  • 500 x Circular Passed PAT Testing Labels
  • 250 x Cable Wrap Labels
  • 250 x Failed PAT Testing Labels

For an overview of the additional items included in this kit, please see the following table.

Item Description   SMARTPAT PAT Tester – PAT Essentials Kit (Bundle 1)

Deluxe Carrying Case

Keep all of your equipment safe and in one place with this large-size carrying case!

(appearance of the case may vary depending on current stock)

Socket Tester

Need to check if your sockets are working right? Just plug this into a standard UK plug socket and if there's a problem, the socket tester will let you know about it!

(socket tester may vary depending on current stock)

eLearning PAT Testing Course - Includes Exam and Certificate

Gain a certificate of competency to carry out PAT testing in just two hours with our online PAT course and exam. Teams of staff may be trained by purchasing the course multiple times; each staff member will be assigned a unique activation code and login.

PASS PAT Testing Logbook

Keep a record of all of your tests with our logbook. The book includes carbon-copied records, allowing you to keep one for yourself and give the other to customers or keep for a reference.

Microwave Leakage Detector

When PAT testing, it's common practice to check microwaves are also not emitting high levels of radiation. With our microwave leakage detector, you'll be able to do this testing with ease.

PASSPTA21 - IEC (C13 Female) 
to Cloverleaf (C6 Male) PAT Adapter

You'll need this adapter to connect your PAT tester to laptop/PC power leads and other similar equipment which has a cloverleaf-shaped connector.

PASSPTA29 - IEC Plug (C14) 
to Cloverleaf (C5) PAT Adapter

This adaptor is used to connect to laptop power supplies, portable projectors and other similar equipment.

PASSPTA28 - IEC Plug (C14) 
to Fig 8 (C7) Pat Adapter

You'll find several appliances such as game consoles, laptop power supplies, audio/visual equipment and more use this type of connector - with this adapter, you can connect them up to your PAT tester.

CK Tools AV05050 5 Piece Insulated Screwdriver Kit

A handy set of insulated screwdrivers (suitable for live working to 1000V) suitable for a wide variety of applications.
Includes 2 x PZ (1 x 80 and 2 x 100mm) + 3 x slotted (3 x 75, 4 x 100 and 5.5 x 125mm) screwdrivers in a carrying case.

WM1 - 500 x Passed PAT Testing Labels

You'll need these every time an appliance passes a test - just tear one off, fill in the fields (appliance ID, your name, test date and next test due date) and stick on the appliance when done.

WM6500 - 500 x Circular Passed PAT Testing Labels

These circular-shaped PAT labels are great for plug tops and any other appliance. The labels also include space for ticking the month/year the next test is due.

WM12 250 - 250 x Cable Wrap Labels

These passed labels wrap around a wire/cable from an appliance and are recommended for use with power supplies or on appliances where you can't stick a label. They also include space for writing your appliance ID, name, test date and next test date.

WM7 250 - 250 x Failed PAT Testing Labels

You won't need these as often as your passed labels, but you'll need to apply one of these whenever an appliance fails a test. If it does fail, the item should be taken out of service for repair or replacement

FREE KEWPAT App Key Features

The KEWPAT App is NOT included with the Kewtech SMARTPAT PAT Tester – PAT Essentials Kit (Bundle 1). However;  it is required in order to transform the Kewtech SMARTPAT PAT Tester into a fully downloadable PAT tester, as well as facilitate the creation of personalised test sequences.

Please see the video and bullet points below for a quick introduction to the KEWPAT App. This app is available to download for free from the App Store (iOS) and Google Play (Android). 

  • FREE app for iOS and Android smartphones
  • Download for FREE from the App Store (iOS) and Google Play (Android)
  • Control the Kewtech SMARTPAT PAT Tester remotely
  • Program and initiate tests remotely
  • Create customised test sequences
  • Specify pass limits, duration and the number of repeats
  • Integrated risk assessment feature allows the user to ascertain the recommended testing frequency of an appliance in accordance with the Code of Practice
  • Testing frequency can be adjusted to include extenuating circumstances, such as dampness
  • Results are sent to the user's smartphone from the SMARTPAT
  • Add additional information to collected results
  • Save records to a database or send them to print
  • Labels can be printed with a company logo
  • Auto-number increment 
  • Drop-down menus for customer, site, location and product description
  • Scan barcodes and QR data codes 
  • New description or repeat
  • Appliance description
  • Images of appliances-under-test can be saved to the product register
  • Voice prompt helps
  • Manage databases
  • Manage customer information
  • Connect to a PC via Wi-Fi
  • Can be used with the EZYPAT and EZYPAT PLUS to collect data and create reports manually (manual mode)
Free Complete Guide to EET (PAT) Testing
  • PASS The Complete Guide to EET (PAT) Testing, 5th Edition - PASS-PAT-HB, typically £24.99

Kewtech EZYPAT/ SMARTPAT Comparision Table

Specification EZYPAT EZYPAT PLUS SMARTPAT
200mA Continuity Test  X X X
250V Insulation Test X X X
500V Insulation Test X X X
Substitute Leakage Test X X X
Polarity Check X X X
110V Load and Run Test X X
230V Load and Run Test X X
Portable RCD Test X
Compatible with KEWPAT App X
Customisable Test Sequences X

Kewtech SMARTPAT PAT Tester - Battery Operated Technical Specifications

Protective Conductor Resistance Test
Measuring range 0.00 - 20.00 Ω (NULL value inc)*
Over-range indication > 20.00 Ω
Resolution 0.01Ω
Open-circuit voltage 5 V ±0.4 V DC
Measuring current 200 mA DC (nominal value)
Accuracy ±3%rdg ±5dgt
* Resistances exceeding 3 Ω cannot be cancelled by NULL function
Mains Voltage 
Display range 30 - 270 V
Hi/ Lo indication < 30 V: No voltage indication > 270 V: 270 V
Resolution & Accuracy 1 V ±3%rdg ±5dgt
Insulation
Rated Voltage  250V 500V
Measuring range 0.00 - 20.00 MΩ
Over-range indicatio > 20.00 MΩ
Resolution 0.01 MΩ
No-load voltage 250 V DC +20%, -0% 500 V DC +20%, -0%
Short-circuit current 1.5 mA DC or less
Rated current 1 -1.2 mA with a load of 0.25 MΩ 1 to 1.2 mA with a load of 0.5 MΩ
Accuracy ±2%rdg±3dgt
Substitute Leakage 
Measuring range 0.10 - 12.00 mA rms
Over-range indication > 12.00 mA
Resolution 0.01mA
Open-circuit voltage/ Freq 30 V ±5 V rms / 50 Hz ±5%
Measuring current 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
Accuracy ±3%rdg±5dgt
Insuyltation Test Between L-N
Open-circuit voltage 4.5 V ±0.5 V DC
Criteria of judgement 100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted
Run Leakage
Item Load Current  Leakage Current
Mains voltage range 100 - 253 V / 50 Hz
Measuring range 0.10 - 13.00 A rms 0.10 - 20.00 mA rms
Display range 0.00 - 13.00 A 0.00 - 20.00 mA
Over-range indication > 13.00 A > 20.00 mA
Resolution 0.01A 0.01mA
Accuracy ±10%rdg ±5dgt ±3%rdg ±5dvgt
Max. rating 3 kVA max. / 15 sec. cont.
RCD Test
Rated voltage 230 V - 15% to +10% / 50Hz
Rated current 10 mA / 30 mA
Test duration ×1: 0.0 ms - 500.0 ms ×5: 0.0 ms - 40.0 ms
Test current accuracy 2% - 8%
Operating time accuracy ±2 ms ( 40 ms) ±8 ms (>40 ms)

Kewtech SMARTPAT PAT Tester - Datasheet Datasheets Kewtech SMARTPAT PAT Tester - Datasheet Datasheets

Reviews

Additional Information
SKU SMARTPATBUNDLE1
Manufacturer Part Code SMARTPATBUNDLE1