The Kewtech EZYPAT PAT Tester can be used to manually conduct dead testing on extension leads, Class I and Class II appliances that do not require a power supply to start up, i.e. items WITHOUT electronic on/off switches.
PLEASE NOTE that the EZYPAT PLUS, available here, is suited to testing items (such as computers and TVs) with electronic on/off switches and which do require a power supply to start up. For more information regarding Kewtech's EZYPAT/SMARTPAT range, please see the comparison table detailed in the 'Technical Specifications'.
Nevertheless, the Kewtech EZYPAT PAT Tester is IT safe as it features a low current, 200mA earth continuity test and 250V DC insulation test.
Moreover, the Kewtech EZYPAT PAT Tester’s accompanying EZYLEAD Extension Lead Adapter and EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip, as well as its Test Lead Null function all allow the user to quickly adapt this product to perform a variety of tests accurately.
Adding to this product’s adaptability is its choice of voltages for insulation tests (250V DC or 500V DC) and selectable substitute leakage test limits.
There are a number of tests available on the Kewtech EZYPAT PAT Tester, including:
The results of these tests are clearly displayed on the Kewtech EZYPAT PAT Tester’s large, backlit display. This display will turn red if an appliance has failed a test and green when an appliance has passed. This display feature adds to the Kewtech EZYPAT’s efficiency and ease-of-use; other features which make using the Kewtech EZYPAT PAT Tester quick and convenient are its automatic test sequences for Class I and Class II appliances and extension leads, and its lightweight, practical design. All these features allow the user to perform numerous tests quickly in a variety of environments.
Finally, the Kewtech EZYPAT PAT Tester's battery operation also works to make this product convenient and practical, as the user is able to perform approximately 1400 tests before the batteries begin to expire. This combined with the Kewtech EZYPAT PAT Tester’s numerous other features, accessories and measurement capabilities make it ideal for providing a solution to basic PAT Testing requirements.
Specification | EZYPAT | EZYPAT PLUS | SMARTPAT |
200mA Continuity Test | X | X | X |
250V Insulation Test | X | X | X |
500V Insulation Test | X | X | X |
Substitute Leakage Test | X | X | X |
Polarity Check | X | X | X |
110V Load and Run Test | X | X | |
230V Load and Run Test | X | X | |
Portable RCD Test | X | ||
Compatible with KEWPAT App | X | ||
Customisable Test Sequences | X |
Protective Conductor Resistance Test | |
Measuring Range | 0.00 - 20.00 Ω (NULL value inc)* |
Over-range Indication | > 20.00 Ω |
Resolution | 0.01Ω |
Open-circuit Voltage | 5 V ±0.4 V DC |
Measuring Current | 200 mA DC (nominal value) |
Accuracy | ±3%rdg ±5dgt |
* Resistances exceeding 3 Ω cannot be cancelled by NULL function. |
|
Insulation | |
Measuring Range | 0.00 - 20.00 MΩ |
Over-range Indication | > 20.00 MΩ |
Resolution | 0.01 MΩ |
No-load Voltage | 250V : 250 V DC +20%, -0% |
500V: 500 V DC +20%, -0% | |
Short-circuit Current | 1.5 mA DC or less |
Rated Current | 250V: 1 -1.2 mA with a load of 0.25 MΩ |
500V: 1 to 1.2 mA with a load of 0.5 MΩ | |
Accuracy | ±2%rdg±3dgt |
Substitute Leakage | |
Measuring Range | 0.10 - 12.00 mA rms |
Over-range Indication | > 12.00 mA |
Resolution | 0.01mA |
Open-circuit Voltage/ Frequency | 30 V ±5 V rms / 50 Hz ±5% |
Measuring Circuit | 1.2 mA AC ±0.5 mA (when measuring 12.00 mA) |
Accuracy | ±3%rdg±5dgt |
Insulation Testy Between L-N | |
Open-circuit Voltage | 4.5 V ±0.5 V DC |
Criteria of Judgement |
100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted. |
Physical Specifications | |
Safety |
IEC/EN61010-1 CAT II 300V-instrument |
EMC | EN61326-1, 2-2 |
Possible number of |
Approx. 1400 times |
Boxed Weight | 1.61Kg |