Professional-grade PAT testing instrument with memory, download and full QWERTY keyboard
An upgraded version of Fluke's 6200 PAT tester, the Fluke 6500 incorporates all of the functionality of the other model and builds upon it to create one of the best PAT testers available on the market today.
The 6500-2 is an upgrade to the original Fluke 6500. New features include:
- Insulation testing at 250V DC
- RCD testing
- Full colour screen
- USB ports for printing and flash drives
- 110V appliance testing
With a range of functions built directly into the tester designed to enhance the testing experience and make life easier, this professional PAT tester ensures that less time is spent testing and more time is spent increasing productivity. Tests are incredibly simple to perform thanks to dedicated, one-touch buttons, built-in memory allows storage of a large amount of measurement data with direct download to PC (no more jotting down test results!) and the built-in full QWERTY keyboard makes it easy to manage and amend stored data.
The 6500 includes a large suite of testing procedures, ensuring compliance with the IET Code of Practice at all times. This tester is capable of performing protective earth resistance, insulation, protective earth conductor current, touch current, substitute leakage current, appliance power (kVA) and appliance load current procedures with each test assigned to an individual button for ease of use.
Exclusive features that are found only on this tester include the abilitity to download to PC, a graphical LCD display with help diagrams, compact flash card receptacle, auto-testing procedures, programmable PASS/FAIL level indicators, real time clock and front panel results management.
Fluke 6500 PAT Tester Key Features
- Dedicated “one-touch” keys for quick testing
- Large backlit display for easy reading
- Single mains socket for appliance connection
- Separate IEC lead socket for easy extension lead testing
- Detachable earth bond test lead for quick changing
- Integrated carrying handle
- QWERTY keyboard for fast data input
- Compact Flash memory card slot for data storage and easy transfer to PC
- 1000 result memory
- Large illuminated display
- Auto-test sequences with pre-set pass and fail values
- Inbuilt site, location and description codes for speedy data input
- Memory review facility to recall your results on-site
What's Included?
- Fluke 6500-2 PAT Tester
- Fluke 6500 Hard Carry Case
- Fluke 6500 Instruction Manual
- Earth Test Lead
- Earth Test Probe
- Crocodile Clip
Fluke 6500 PAT Testing Kits
The Fluke 6500 is a great tester for any professional - but you're going to need accessories as well when you're out PAT testing. Thankfully our exclusive, low-cost PAT testing kits come with a Fluke 6500 and a bundle pack of accessories designed to complement the tester.
Just use the table below to compare out available options for this product:
Item | PAT Essentials Kit (Bundle 1) | PAT Business Kit (Bundle 2) |
PAT Premium Kit (Bundle 3) |
---|---|---|---|
UNI-T UT07A Socket Tester Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
Yes | Yes | Yes |
CK Tools AV05050 Screwdriver Set This bundle pack includes a set of 5 fully insulated electrical screwdrivers which are suitable for live electrical work to 1000V |
Yes | Yes | Yes |
PAT Testing Training DVD + Online Examination for 1 Person Not trained to perform PAT testing? With our training DVD, you can learn from your workplace or at home how to PAT test! |
Yes | Yes | Yes |
PASS PAT Testing Handbook A comprehensive, extremely detailed guidebook with useful information, diagrams, pictures and case studies related to PAT testing. |
Yes | Yes | Yes |
Microwave Leakage Detector It's common practice to check microwave radiation levels while you're PAT testing - use this portable, easy-to-use microwave leakage detector to do so |
Yes | Yes | Yes |
IEC Adapter Set A special bundle pack with three IEC adapters, allowing you to use your PAT tester with various types of IEC cables and power supplies |
Yes | Yes | Yes |
110V Adapter Set Use these two 110V connector leads to connect your PAT tester to 110V equipment commonly found on construction sites and similar applications |
Yes | Yes | Yes |
Passed PAT Testing Labels A PAT essential! We include two 500 label rolls in your purchase, ensuring you have everything you need for labelling appliances after testing |
Yes, 1000x | Yes, 1000x | Yes, 1000x |
Circular Passed PAT Labels Uniquely-designed passed PAT testing labels with circular design - ideal for smaller plugs or appliances where you can't easily fit other labels |
Yes, 500x | Yes, 1000x | Yes, 1000x |
PAT Testing Cable Wrap Labels These labels wrap around cables, and are great for labelling appliance power leads where you can't fix a suitable label |
Yes, 500x | Yes, 500x | Yes, 500x |
Failed PAT Testing Labels You won't need these very often, but if an appliance ever fails testing you should place one of these labels and take it out of use for repair or replacement |
Yes, 500x | Yes, 500x | Yes, 500x |
Visual Inspection Labels You should check your appliances over for obvious signs of damage before testing. Look for frayed wires, loose connection and damaged plugs, then place one of these labels on if the appliance passes |
No | Yes | Yes |
SimplyPATS Software Download and interact with your results on your PC with this software package. Ideal for creating records, reports and much more. |
No | Yes | No |
Barcode Scanner Easily speed up your record keeping with this USB barcode scanner for use with your Fluke 6500-2! |
No | No | Yes |
Barcode Labels Use these with the included barcode scanner to speed up your testing times |
No | No | Yes, 2000x |
Fluke 6500-2 Technical Specifications
Test Specifications | The accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75 % RH. | |
Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C. | ||
The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2. | ||
Power-on Test | The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency. | |
Display Range | 90 V to 264 V | |
Accuracy at 50 Hz | ± (2% + 3 counts) | |
Resolution | 0.1 V | |
Input Impedance | > 1 MΩ // 2.2 nF | |
Maximum Input Mains Voltage | 264 V | |
Earth Bond Test (Rpe) | Display Range | 0 to 19.99 Ω |
Accuracy (After Bond Test Zeroing) | ± (2.5% + 4 counts) | |
Resolution | 0.01 Ω | |
Test Current | 200 mA AC -0% +40% into 1.99 Ω 25 A AC ± 20% into 25 mΩ at 230 V |
|
Open Circuit Voltage | > 4 V AC, < 24 V AC | |
Bond Test Zeroing | can subtract up to 1.99 Ω | |
Insulation Test (Riso) | Display Range | 0 to 299 MΩ |
Accuracy | ± (5% + 2 counts) from 0.1 to 300 MΩ | |
Resolution | 0.01 MΩ (0 to 19.99 MΩ) 0.1 MΩ (20 to 199.9 MΩ) 1 MΩ (200 to 299 MΩ) |
|
Test Voltage | 500 V DC -0% + 25% at 500 kΩ load or 250 V dc -0 % +25 % at 250 kΩ load | |
Test Current | > 1 mA at 500 kΩ load, < 15 mA at 0 Ω | |
Auto Discharge Time | < 0.5 s for 1 μF | |
Max. Capacitive Load | Operational up to 1 μF | |
Touch Current Test | Display Range | 0 to 1.99 mA AC |
Accuracy | ± (4% + 2 counts) | |
Resolution | 0.01 mA | |
Internal Resistance (via Probe) | 2 kΩ | |
Measuring Method | Probe* | |
Substitute Leakage Current Test | Display Range | 0 to 19.99 mA AC |
Accuracy | ± (2.5% + 3 counts) | |
Resolution | 0.01 mA | |
Test Voltage | 100 V AC ± 20% | |
Load/Leakage Test: Load Current | Display Range | 0 A to 13 A |
Accuracy | ± (4% + 2 counts) | |
Resolution | 0.1 A* | |
Load/Leakage Test: Load Power | Display Range 230 V Mains | 0.0 VA to 3.2 kVA |
Accuracy | ± (5 % + 3 counts) | |
Resolution | 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)* | |
Load/Leakage Test: Leakage Current | Display Range | 0 to 19.99 mA |
Accuracy | ± (4% + 4 counts) | |
Resolution | 0.01 mA* | |
PELV Test | Accuracy at 50 Hz | ± (2% + 3 counts) |
Overload Protection | 300 V rms | |
Warning Threshold | 25 V rms | |
RCD Test: Trip Current | Operational Error | ±10 % |
Nominal | 30 mA | |
Accuracy | ±5 % | |
RCD Test: Trip Time | Standard Requirement | 61557 Part 6; tolerance of rated test current 0 % to +10 % |
Operational Error | ±10 % | |
RCD Type | AC general-purpose 30 mA | |
Display Range | 310 ms | |
Resolution | 0.1 ms | |
Accuracy | 3 ms | |
Trip Time Limit at 100 % (30 mA) | 300 ms | |
Trip Time Limit at 500 % (150 mA) | 40 ms | |
*The appliance under test is energized at mains potential. |
Environmental Specifications |
|
Operating Temperature | 0 to 40 °C |
Relative Humidity | Non condensing < 10 °C 95% from 10 to 30 °C 75% from 30 to 40 °C |
Safety Specifications |
|
Safety Rating | Complies with EN61010-1 3rd edition |
CAT II, 300 V, pol 2 |
Mechanical & General Specifications |
||
Size | 200 mm (L) x 275 mm (W) x 114 mm (H) | |
Weight | 3.13 kg | |
Power Supply | 230 V +10 % -15 %, 50 Hz ±2 Hz or (6500-2 only: 110V +10 % -15 %,50 Hz ±2 Hz) | |
Power Consumption (Tester) | 13 W typical (idle) 60 W max. during 25A Bond test |
|
Storage | Temperature | -10 to 60 °C |
Corrosion | 70 °C @ 95 % RH for 5 days max. | |
Operating Altitude | 0 up to 2000 m | |
Sealing | IP-40 (enclosure), IP-20 (connectors) | |
EMC | Complies with EN61326-1, portable | |
EMI Immunity | 3 V/m |
Reviews
SKU | FLUKE-6500-2 UK/PASS |
---|---|
Manufacturer Part Code | 4324475 |
Model No | 6500-2 |
Country of Origin | United Kingdom |