The Seaward Apollo 600+ PAT Tester Elite Bundle Kit & PAT Guard 3 Software includes:
For further information regarding these products, please see the descriptions below.
The Seaward Apollo 600+ PAT Tester is suitable for conducting health and safety checks and ensuring that appliances are compliant with the IET 5th Edition Code of Practice. It is capable of performing a comprehensive selection of tests, including:
The tester also includes a risk-based retest period calculator which allows the user to ascertain the retest period of each appliance according to the IET 5th Edition Code of Practice. In addition to this, the Seaward Apollo 600+ PAT Tester is able to accommodate up to 100 user-customised electrical test and visual inspection sequences. The results gathered from these tests may be saved to the Apollo 600+’s extensive memory, the largest of all the models in the Apollo+ series. It has the capacity to save up to 50 000 results and 2000 images.
As the Seaward Apollo 600+ PAT Tester has been optimised for health and safety applications, it includes a number of features designed for this purpose. These features are not found on its sister products the Apollo 400+ and 500+ and include:
The images and records taken using the Seaward Apollo 600+ PAT Tester can be transferred to a PC via a USB cable, sent to an Android device via Bluetooth, or downloaded directly to a USB drive.
For further information, please see below.
Hardware Features
The Seaward Apollo 600+ PAT Tester includes a removable, rechargeable, interchangeable battery pack designed to reduce downtime. Furthermore, this tester can also be powered using a mains supply.
It is supplied with sturdy test probes and test leads with a strong PVC insulation, making the Seaward Apollo 600+ PAT Tester suitable for more demanding applications.
Firmware Features
The Seaward Apollo 600+ PAT Tester can be used to read and print 2D QR data codes when used with selected Seaward tools:
The Seaward Apollo 600+ PAT Tester is a sophisticated, versatile and adaptable tester optimised for checking high-volumes of appliances and conducting health and safety checks.
In order to read and/or print 2D QR data codes, the Seaward Apollo 600+ PAT Tester must be used with the Seaward Test ‘n’ Tag Elite 2 Printer and/or Seaward 2D Bluetooth Barcode Scanner included in this kit.
The Seaward Test ‘n’ Tag Elite Bundle Kit includes:
The Seaward Test ‘n’ Tag Elite Bundle Kit is ideal for extending the versatility of the Seaward Apollo 600+ PAT Tester.
Like the Seaward Apollo 600+ PAT tester, the Seaward PAT Guard 3 Software is optimised for health and safety applications. It can be used to organise the results and images taken using the Apollo 600+ into reports, as well as generate certificates and manage assets.
It includes the following features and capabilities:
The comprehensive PAT Guard 3 Software is ideal for duty holders, in-house PAT testers, health and safety managers, health and safety contractors, professional PAT testers, electrical contractors, facilities managers, risk assessment professionals and operations managers. It is ideal for organising, analysing and evaluating the data acquired by the Seaward Apollo 600+ PAT Tester.
Earth Continuity | |
Test Current | ±200mA DC |
Display Range | 0.01 to 19.99Ω |
Pass Value | User defined |
Insulation Resistance | |
Test Voltage | 500V / 250V DC @ 1mA nominal |
Display Range | 0.01MΩ to 19.99MΩ |
Pass Value | User defined |
IEC Lead Test | |
Test Voltage | 5V AC nominal |
Test | Live/neutral checks for o/c, s/c and crossed |
Protective Conductor Current/Load | |
Test Voltage | Supply voltage, maximum load current 16A |
Display Range | 0.01mA to 19.99mA |
Pass Value | User defined |
Touch Current | |
Test Voltage | Supply voltage, maximum load current 16A |
Display Range | 0.00 to 5mA |
Pass Value | User defined |
Load Power/Current | |
Test Voltage | 230V + 10%, maximum load current 16A |
Test Duration | Programmable up to a maximum of 255s depending on load. i.e. max duration is reduced for high loads |
Display Range | 0.00kVA to 4.00kVA 0.00A to 16.00A |
Alternative Leakage Current | |
Test Voltages | >25V AC <50V AC |
Display Range | 0.00mA to 19.99mA |
Pass Value | User defined |
RCD Test | |
Test Voltage | 230V + 10%, -15% |
Test Current | 15mA/30mA rms sinusoidal |
Display Range | 0ms to 2000ms |
Test Method | Internal isolation to avoid tripping distribution board RCDs |
Power Socket Test | |
Voltage Range | 207V to 253V AC |
Indication of Voltage Potential | Line potential phase to earth Line potential phase to neutral Line potential neutral to earth |
General Specifications | |
Memory Size | 50000 records + 2000 photos |
Weight | 1.5kg |
Dimensions | 230 x 150mm x 100mm |
Power Source | Mains or rechargeable battery pack |
General Features | 600+ | 500+ | 400+ |
Battery & mains powered | • | • | • |
Colour screen & QWERTY keypad | • | • | • |
Large internal memory | up to 50,000 records and 2,000 photos | up to 10,000 records | up to 2,000 records |
Bluetooth scanner & printer compatible | • | • | • |
Password controlled user accounts | • | • | |
Set up multiple user accounts with varying levels of privileges | • | • | |
Clone facility to set up multiple testers | • | • | |
Checkbox supplied as standard | • | • | |
Test Inspection Features | 600+ | 500+ | 400+ |
Auto-increment asset ID | • | • | |
PAT Setup option to allow for custom menus | • | • | |
Enter asset description after test using the keypad or barcode scanner | • | • | • |
Comprehensive electrical safety test features | • | • | • |
Point to point measurement (Rpe & IR) | • | • | Optional accessory required |
User configurable electrical test/visual inspection sequences | 100 | 100 | 25 |
User set sites & locations | 100 | 100 | 50 |
Risk-based retest period calculator | • | • | |
User definable comments lines against test records | 4 | 4 | |
Configurable checklists for any workplace test or inspection (user tests) | • | • | |
Onboard camera | • | ||
Universal risk assessment | • | ||
Health & safety certificates | • | ||
Data Transfer | 600+ | 500+ | 400+ |
1D and 2D Scanner connectivity | • | • | Reads 1D Data Only |
Read QR code (2D) labels with 2D scanner | • | • | |
RFID reader connectivity | • | • | |
Print Pass & Fail labels with 1D barcode | • | • | • |
Print Pass & Fail labels with QR code (2D) | • | • | |
Add your company logo to labels (on large 1D labels only) | • | • | |
Select from various label formats to print | 6 | 6 | 6 |
Download to PC via USB cable | • | • | • |
Data Transfer via USB flash drive | • | ||
Filter results to be downloaded | • | • | • |
Upload previous results to the tester for a retest | • | • |
System Requirements | IBM compatible PC |
Processor speed 500Mhz or higher | |
Microsoft Windows XP/Vista/7/8/10 | |
512Mb RAM | |
50Mb available hard disk space | |
Colour monitor with 32-bit colour or greater video card | |
Internet connection or CD ROM drive | |
Internet Explorer 8 or later |